SPECIFICATIONS
STRUCTURE
Reinforced Concrete Framework
WALLS
Clay Brick
ROOFS
Reinforced Concrete Slab / Metal Roof Sheeting
CEILING FINISHES
Lift Lobby - Fibre Board Plaster Ceiling
Corridor - Fibre Board Plaster Ceiling
Office - No Ceiling Provided
Toilet - Fibre Board Plaster Ceiling
DOORS
Office Entrance - Fire-rated Door
Staircase - Fire-rated Door
Others - Timber Flush Door
FLOOR FINISHES
Ground Floor Lift Lobby - Granite
Tower Lift lobby - Homogenous Tiles
Corridor - Homogenous Tiles / Carpet Tiles
Office - Power Float Finish / Bare Concrete
Toilet - Homogenous Tiles
WINDOWS
Aluminium Powder Coated Frame with Tinted Glass
WALL FINISHES
External Wall - Granite / Spray Tile / External Paint
Internal Wall:
Ground Floor Lobby - Granite with Stainless Steel
Tower Lift Lobby - Ceramic Tiles / Plaster with Emulsion Paint
Corridor - Plaster with Emulsion Paint
Office - Plaster with Emulsion Paint
Toilet - Ceramic Tiles / Plaster with Emulsion Paint
Others - Plaster with Emulsion Paint
SANITARY FITTINGS
White Ceramic
ELECTRICAL INSTALLATION
Distribution Board with incoming 60A single-phase or 30A three phase supply
TELEPHONE INSTALLATION
Telephone Distribution Board with 6 pairs of wires